Products

Products Home
FTOS
E-Series
E-Series Line Cards
C-Series
C-Series Line Cards
S-Series
P-Series
Media Specifications
Testing Reports
Network Management
Customer Profiles
Testimonials
White Papers
Force10 Images/Photos
Force10 EULA

 

Contact Our Sales Team
    +1 866 600 5100
    +1 408 965 5100

S50V (Access Switch)

S-Series S50v Access Switch
  • 48-port GbE fixed configuration 1-RU switch
  • Up to four 10 GbE uplinks
  • Scalable stacking technology supports 144 GbE ports in up to three S50s
Overview
Specifications
Line Cards
f10
 

S50V Overview

 

S-Series S50V High Performance GbE/10 GbE Access Switch

The Force10 S50V brings core-like resiliency in a compact form factor to the network edge, enabling cost-effective scalability. With PoE and low switching latency, the high density Gigabit Ethernet switch delivers the critical functionalities that advanced enterprise network edges demand.

Key Applications

Coupled with the E-Series, which delivers unmatched resiliency and performance, the S50V enables IT managers to deploy a reliable end-to-end 10 GbE solution that spans from core to network edge.

  • Line-rate GbE and 10 GbE rack switches for the most demanding data center, storage or compute facility
  • PoE-ready for wiring closets that require core resiliency and high availability for VoIP and wireless connectivity
  • Small form factor POP Layer 2 interconnects leveraging 10 GbE LAN PHY for cost effective metro or intra-POP transport

Key Features

The S50V is a PoE ready fixed configuration switch that delivers the reliability and scalability that wiring closets demand.

  • 48 10/100/1000 ports in a 1-RU form factor
    • 44 ports 10/100/1000Base-T
    • 4 ports 10/100/1000Base-T shared with SFP pluggable optics
    • IEEE802.3af compliant PoE that provides up to 15.4W per port and 320W per switch
  • Optional Modules
    • 2-port 10 GbE LAN PHY (pluggable XFP modules)
    • 2-port 10 GbE (CX4)
    • 2-port 12 Gbps stacking
    • 1-port 24 Gbps stacking
  • Switching fabric capacity of 288 Gbps and forwarding capacity of more than 131 Mpps
  • Stack up to three S50Vs to deliver a scalable high capacity solution
  • Supports Jumbo frames of up to 9,216 bytes; ideal for high-end server connectivity and network attached file servers
  • Full complement of standards-based Layer 2 and Layer 3 features
  • Built-in power redundancy

S50V Specifications

 

Physical

  • 48 line-rate ports 10/100/1000Base-T
  • 4-ports SFP (shared)
  • 1 RJ-45 Console/management port with RS-232 signaling
  • Optional Modules:
    • 2 line-rate ports 10 Gigabit Ethernet XFP
    • 2 line-rate ports 10 Gigabit Ethernet CX4
    • 2 line-rate ports 12 Gigabit Stacking
    • 1 line-rate port 24 Gigabit Stacking
  • Size: 1 RU, 1.7 h x 17.32 w x 16.73" d
    (4.3 h x 44 w x 42.5 cm d)
  • Weight: 15.62 lbs (7.10 kg)
  • Power Supply:
    • 100 - 240 VAC 50/60 Hz
    • -48V Terminal Type DC
  • Maximum thermal output: 407 BTU/hr
  • Maximum Current Draw per System:
    • 4 A at 100/120 VAC
    • 2 A at 200/240 VAC
  • Maximum power consumption: 470W
  • 19" rack mountable
  • Standard 1U chassis height
  • Maximum Operating Specifications:
    • Temperature: 14° to 131°F (–10° to 55°C)
    • Operating humidity: 10 to 90% (RH), non-condensing
  • Maximum Non-operating Specifications:
    • Storage Temperature: –40° to 158°F (–40° to 70°C)
    • Storage humidity: 10 to 90% (RH), non-condensing
  • Reliability: MTBF 130,000 hours

Redundancy

  • Redundancy in stack connectivity (self healing ring)
  • Redundancy with up to 4 ports of 10 GbE uplinks
  • Redundancy with dual modular slots
  • Redundancy with link aggregation across stack members
  • Power redundancy

Performance

  • Layer 2 MAC Addresses: 16K
  • Layer 3 Forwarding Entries: Up to 3K LPM table and 4K host entries
  • Switching Fabric Capacity: 288 Gbps
  • User traffic capacity: 176 Gbps (131 Mpps)
  • Jumbo Frame Support: 9216 bytes
  • Link Aggregation: 8 links per Link Aggregation Group and 48 groups per system
  • Stacking capacity: Up to 96 Gbps
  • Queues per port: 8 Queues (8th queue reserved for stacking)
  • VLANs: 1024 VLANs with 4096 tag value support
  • Line-rate Layer 2 switching: all protocols, including IPv4 and IPv6
  • Line-rate Layer 3 routing: IPv4
  • LAG load balancing based on Layer 2, IPv4 or IPv6 headers

IEEE Compliance

  • 802.1AB Link Layer Discovery Protocol
  • 802.1D Bridging, STP
  • 802.1p L2 Prioritization
  • 802.1Q VLAN Tagging
  • 802.1s Multiple Spanning Tree Protocol
  • 802.1w Rapid Spanning Tree Protocol
  • 802.1X Network Access Control
  • 802.3ab Gigabit Ethernet (1000BASE-T)
  • 802.3ad Link Aggregation with LACP
  • 802.3ae 10 Gigabit Ethernet
  • 802.3ak 10 Gigabit Ethernet (10GBASE-CX4)
  • 802.3af Power over Ethernet
  • 802.3i Ethernet (10BASE-T)
  • 802.3u Fast Ethernet (100BASE-TX)
  • 802.3x Flow Control
  • 802.3z Gigabit Ethernet (1000BASE-X)

RFC Compliance

OSPF:
  • 1765 OSPF Database overflow
  • 1850 OSPF MIB
  • 2154 OSPF MD5
  • 2328 OSPF v2
RIP:
  • 1058 RIP v1
  • 1724 RIP MIB
  • 2082 RIP MD5
  • 2453 RIP v2
IP Multicast:
  • 1112 IGMP
  • 2236 IGMPv1 and v2
  • 2362 PIM-SM
  • 3376 IGMPv3
  • Ietf-draft IGMP-snooping
    v1 and v2

RFC Compliance (con't)

General Routing and Switching Protocols:

  • 768 UDP
  • 783 TFTP
  • 791 IP
  • 792 ICMP
  • 793 TCP
  • 826 ARP
  • 854 Telnet
  • 894 IP over Ethernet
  • 903 Reverse ARP
  • 951 BootP
  • 1027 Proxy ARP
  • 1256 ICMP
  • 1519 CIDR
  • 1542 BootP (relay)
  • 1812 IP v4 routers
  • 2030 SNTP
  • 2131 BootP/DHCP helper
  • 2236 IGMP v1 and v2
  • 2338 VRRP

Security:

  • 1492 TACACS+
  • 2865 RADIUS
  • 3128 Protection Against a Variant of the Tiny Fragment Attack

Port Security

  • Ietf-draft SSH v2
  • SSL
  • Layer 2/3/4 ACLs
  • IP Broadcast Control
Quality of Service:
  • 7 user queues per port
  • IEEE 802.1p
  • IP DiffServ support
  • Per port rate limiting
  • Per queue rate limiting
  • Strict Priority and Weighted Round Robin Scheduling

Management and SNMP:

  • RADIUS/TACACS+ Authentication
  • Industry familiar CLI with
    • Scripting
    • Command completion
    • Context sensitive help
  • 1157 SNMP v1
  • 1212 Concise MIB Definition
  • 1213 SNMP v2 (MIB-II)
  • 1493 Bridge MIB
  • 1643 Ethernet-like MIB
  • 1901 Community based SNMPv2
  • 1905 Protocol Operations for SNMPv2
  • 1906 Transport Mappings for SNMPv2
  • 1907 Management Information Base for SNMPv2
  • 1908 Coexistence between SNMPv1 and SNMPv2
  • 1724 RIP v2 MIB extension
  • 1850 OSPF v2 MIB
  • 2096 IP forwarding table MIB
  • 2233 The Interfaces Group MIB using SMI v2
  • 2570 SNMP v3
  • 2665 Ethernet-like interfaces
  • 2674 VLAN MIB
  • 2787 VRRP MIB
  • 2819 RMON (Groups 1,2,3,9)
  • 2933 IGMP MIB
  • 2934 PIM MIB for IPv4

Compliances

Safety
  • CUS 60950, 3rd edition (US NRTL through CSA)
  • CSA 60950, 3rd edition
  • CE Mark (EN 60950)
  • CB Report, all country deviations
  • EN 60825-1 Safety of Laser Products-Part 1:
    • Equipment Classification Requirements and User's Guide
  • EN 60825-2 Safety of Laser Products-Part 2:
    • Safety of Optical Fibre Communications Systems
  • 21 CFR 1040.10 and 1040.11 FDA laser device requirements
EMC
  • USA: FCC CFR47 Part 15, Subpart J, Class A
  • Canada: ICES-003, Issue-2, Class A
  • Europe: EN55022 1998 (CISPR 22: 1997), Class A
  • Japan: VCCI V3/01.4 Class A
  • EN 61000-4-2 ESD
  • EN 61000-4-3 Radiated Immunity
  • EN 61000-4-4 EFT
  • EN 61000-4-5 Surge
  • EN 61000-4-6 Low Frequency Conducted Immunity
  • EN 300 386 V1.3.1 (2001-09) EMC for Network Equipment
  • EN 55024 1998
Telecoms
  • JATE (for Japan)

RoHS Compliance

All S50V components are EU RoHS compliant with the exception of lead, which is exempt from the directive for network equipment.
 

Ordering Information

 
  • Order Number
  • Description
  • S50-01-GE-48T-V
     
  • 48-port 10/100/1000BaseT chassis with four SFP ports, two modular slots and PoE
  • S50-01-10GE-2P
  • 2-port 10 GbE XFP module*
  • S50-01-10GE-2C
  • 2-port 10 GbE CX4 module*
  • S50-01-12G-2S
  • 2-port 12 Gbps stacking module*
  • S50-01-24G-1S
  • 1-port 24 Gbps stacking module*
  • S50-01-SSC-12G
  • 60cm stacking cable for S50-01-12G-2S
  • S50-01-LSC-12G
  • 4m stacking cable for S50-01-12G-2S
  • S50-01-SSC-24G
  • 60cm stacking cable for S50-01-24G-1S
  • S50-01-LSC-24G
  • 4m stacking cable for S50-01-24G-1S
  • S50-01-PSU-V
     
  • Redundant power supply unit*,
    includes one cable
  • S50-01-SW-L3
  • Layer 3 software upgrade*

  • *Optional component for the S50V
 
back to top >
Downloads
S50V Datasheet