C-Series (Resilient Switches)

C-Series
  • Modular Force10 Operating System (FTOS) software delivers inherent stability
  • In-service diagnostics and traffic visibility tools increase control of network
  • Line-rate, non-blocking 10 GbE performance
Overview
Line Cards
Specifications
Order Info
f10
 

[+|-] C-Series Overview

 

[+|-] C-Series Product Matrix

 
  •  
  • C300
    C300
  • C150
    C150
  • Switch Fabric Capacity
  • 1.536 Tbps
  • 768 Gbps
  • Full-Mesh Forwarding Capacity
  • 952 Mpps
  • 476 Mpps
  • I/O Line Card Slots
  • 8
  • 4
  • Line-rate
    10/100/1000
    Base-T with Class 3 IEEE 802.3af PoE
  • 384 Ports at 15.4W
  • 192 Ports at 15.4W
  • Line-rate
    100Base-FX or GbE SFP
  • 384
  • 192
  • Line-rate 10 GbE XFP
  • 64
  • 32
  • Chassis Size
  • 13 Rack Units

    3 Units/19" Rack
  • 9 Rack Units

    4 Units/19" Rack
  • Hardware Redundancy
  • Power, Route Processor, Switch Fabric,
    Passive Copper Backplane
  • Operating System
  • Fully Modular
 
 

C-Series Specifications

 

Chassis

C300
  • 8 Line card slots
  • 2 Switch fabric and route processor module slots
  • 8 Power supply module slots
  • 1 Fan tray slot
  • Size:
    13 RU, 22.7 h x 17.4 w x 14.4" d
    (57.66 h x 37.58 w x 44.20 cm d)
  • Weight with factory-installed components: 55 lbs (24.95 kg)
  • Weight fully loaded: 152.27 lbs (69.07 kg)
  • AC Power
    • Nominal input voltage:
      100 - 240 VAC 50/60 HZ
    • Maximum thermal output:
      • 9,328 W (8,089 BTU/h) at 100/120 VAC
      • 9,111 W (7,895 BTU/h) at 200/220 VAC
  • Maximum input current per module:
    • 14 A at 100 VAC
    • 12 A at 120 VAC
    • 7 A at 200 VAC
    • 6 A at 240 VAC
  • Maximum system power input:
    • 9.4 KVA at 100/120 VAC
    • 9.2 KVA at 200/240 VAC
  • Maximum power consumption:
    • 9,428 W at 100/120 VAC
    • 9,211 W at 200/240 VAC
C150
  • 4 Line card slots
  • 2 Switch fabric and route processor module slots
  • 6 Power supply module slots
  • 1 Fan tray slot
  • Size:
    9 RU, 15.7 h x 17.5 w x 15.3" d
    (39.88 h x 44.45 w x 38.86 cm d)
  • Weight with factory-installed components: 38 lbs (17.24 kg)
  • Weight fully loaded: 86.63 lbs (39.29 kg)
  • AC Power
    • Nominal input voltage:
      100 - 240 VAC 50/60 HZ
    • Maximum thermal output:
      • 4,899 W (4,647 BTU/h) at 100/120 VAC
      • 4,785 W (4,536 BTU/h) at 200/220 VAC
  • Maximum input current per module:
    • 14 A at 100 VAC
    • 12 A at 120 VAC
    • 7 A at 200 VAC
    • 6 A at 240 VAC
  • Maximum system power input:
    • 4.9 KVA at 100/120 VAC
    • 4.8 KVA at 200/240 VAC
  • Maximum power consumption:
    • 4,949 W at 100/120 VAC
    • 4,835 W at 200/240 VAC
Common
  • 19" front rack mountable
  • Maximum operating specifications:
    • Temperature: 32° to 104°F
      (0° to 40°C)
    • Altitude: no performance degradation to 10,000 feet
      (3,048 meters)
    • Relative humidity: 5 to 85 percent, noncondensing
    • Shock: Bellcore GR-63
    • Vibration: Bellcore GR-63
  • Maximum non-operating specifications:
  • Temperature: -40° to 158°F (-40° to 70°C)
  • Maximum altitude: 15,000 feet (4,572 meters)
  • Relative humidity: 5 to 95 percent, noncondensing
  • Vibration: Bellcore GR-63

Redundancy/Availability

  • 1+1 redundant Switch Fabric & Route Processor Modules (RPM)
  • C300:
    • 2+1 redundant system power supply modules
    • 4+1 redundant PoE Power Supply Modules supporting up to 384 PoE ports at 15.4W with deterministic failure mode
  • C150:
    • 1+1 redundant system power supply modules
    • 2+2 redundant PoE Power Supply Modules supporting up to 192 PoE ports at 15.4W with deterministic failure mode
  • Online insertion and removal of all components Environmental self-monitoring
Performance
  • Layer 2 MAC addresses: 16K
  • Layer 3 forwarding entries: 12K
  • Switching fabric capacity:
    • C300: 1,536 Tbps
    • C150: 768 Gbps
  • Forwarding performance:
    • C300: 952 Mpps
    • C150: 476 Mpps
  • Jumbo frame support: 9252 bytes
  • Link aggregation: 8 links per group & 128 groups per chassis
  • Queues per port: 4 queues
  • VLANs: 4096
  • Line-rate Layer 2 switching: all protocols, including IPv4 and IPv6
  • Line-rate Layer 3 routing: IPv4
  • LAG load balancing based on Layer 2, IPv4 or IPv6 headers

IEEE Compliance

  • 802.1AB Link Layer Discovery Protocol
  • 802.1D Bridging, STP
  • 802.1p L2 Prioritization
  • 802.1Q VLAN Tagging, Double VLAN Tagging, GVRP
  • 802.1s Multiple Spanning Tree Protocol
  • 802.1w Rapid Spanning Tree Protocol
  • 802.1X Network Access Control
  • 802.3ab Gigabit Ethernet (1000BASE-T)
  • 802.3ac Frame Extensions for VLAN Tagging
  • 802.3ad Link Aggregation with LACP
  • 802.3ae 10 Gigabit Ethernet
  • 802.3af Power over Ethernet
  • 802.3ak 10 Gigabit Ethernet (10GBASE-CX4)
  • 802.3i Ethernet (10BASE-T)
  • 802.3u Fast Ethernet (100BASE-TX, 100BASE-FX)
  • 802.3x Flow Control
  • 802.3z Gigabit Ethernet (1000BASE-X)

RFC Compliance

OSPF
  • 1587 NSSA option
  • 2154 OSPF MD5
  • 2328 OSPF v2
  • 2370 Opaque LSA option
RIP
  • 1058 RIP v1
  • 2453 RIP v2
General Routing and Switching Protocols
  • 768 UDP
  • 783 TFTP
  • 791 IP
  • 792 ICMP
  • 793 TCP
  • 826 ARP
  • 854 Telnet
  • 959 FTP
  • 1027 Proxy ARP
  • 1305 NTP v3
  • 1519 CIDR
  • 1542 BootP (relay)
  • 1591 DNS client
  • 1812 IPv4 routers
  • 2131 BootP/DHCP helper
  • 2338 VRRP
  • 3176 sFlow
  • ietf-draft Bidirectional Forwarding Detection
IP Multicast
  • ietf-draft IGMP Snooping
Security
  • 1492 TACACS+
  • 2865 RADIUS
  • 3128 Protection Against a Variant of the Tiny
  • Fragment Attack
  • Secure Copy (SCP)
  • SSH v1/v2
SNMP/MIBs
  • 1157 SNMP v1
  • 1213 SNMP v2 (MIB-II)
  • 1215 Traps for use with SNMP
  • 1493 Bridges
  • 1573 Interfaces group MIB
  • 1757 RMON
  • 1907 MIB for SNMPv2
  • 2011 SNMPv2 IP MIB
  • 2012 SNMPv2 TCP MIB
  • 2013 SNMPv2 UDP MIB
  • 2233 Interfaces MIB
  • 2574 SNMPv3 USM
  • 2575 SNMPv3 VACM
  • 2576 Coexistence between SNMPv1/v2/v3
  • 2665 Ethernet-like interfaces
  • 2787 VRRP MIB
  • Fault management (alarms & status reporting)
  • Force10 Link aggregation MIB
  • Force10 chassis MIB
  • Force10 SNMP copy MIB
  • Force10 monitoring MIB
  • Force10 interface extensions MIB

Compliances

Safety
  • CUS 60950, 3rd edition (US NRTL through CSA)
  • CSA 60950, 3rd edition
  • CE Mark (EN 60950-1)
  • CB Report, all country deviations
  • EN 60825-1 Safety of Laser Products-Part 1:
    • Equipment Classification Requirements and User's Guide
  • EN 60825-2 Safety of Laser Products-Part 2:
    • Safety of Optical Fibre Communications Systems
  • 21 CFR 1040.10 / 1040.11 FDA laser device requirements
EMC
  • USA: FCC Part 15, Class A
  • Canada: ICES-003, Class A
  • Europe: EN55022 1998, Class A
  • Japan: VCCI Class A
  • ANZ: N17576
  • EN 55024 1998

RoHS Compliance

All C-Series components are EU RoHS compliant with the exception of lead, which is exempt from the directive for network equipment.

 

 

  • Order Number
  • Description
  • CH-C150
  • C150 4-slot Chassis with Backplane
  • CH-C300
  • C300 8-slot Chassis with Backplane
  • CC-C150-FAN
  • C150 Fan Subsystem
  • CC-C300-FAN
  • C300 Fan Subsystem
  • LC-CB-RPM
     
  • C300 Switch Fabric and Route Processor Module
    (series CB)
  • LC-CB-10GE-4P
     
  • 4-port 10 Gigabit Ethernet line-card, XFP modules required (series CB)
  • LC-CB-10GE-8P
     
  • 8-port 10 Gigabit Ethernet line-card, XFP modules required (series CB)
  • LC-CB-GE-48P
     
  • 48-port Gigabit Ethernet line card, SFP modules required (series CB)
  • LC-CB-GE-48T
     
  • 48-port 10/100/1000Base-T line card with RJ45 interfaces (series CB)
  • LC-CB-GE-48V

  • 48-port 10/100/1000Base-T line card with RJ45 interfaces and PoE (series CB)
  • CC-C-1200W-AC*
  • 1200W Power Supply Module
  • SW-CB-LATEST
  • FTOS software
 

* Country-specific power cables are additional
* Only Force10 power cables are supported

 